Long-Term Reliability and System Strength Services for the North Country
Western Power · Ref VP524329 · Australia (Commonwealth)
Published 7 September 2026 · Utilities · Value not stated
- Reference number
- VP524329
- Contact person
- Peter Ling Email: peter.ling@westernpower.com.au Tel: 0893266185
- Specification documents
- 3
- Issued by
- Western Power
Tender Details Reliability and System Strength Services for the North Country (Long-Term) - WS5659204351
The Coordinator of Energy has determined, under clause 3.11A.4 of the Electricity System Market (ESM) Rules, to trigger a Non-Co-optimised Essential System Services (NCESS) procurement process by Western Power for Reliability and System Strength Services for the North Country. The proposed services aim to address reliability and system strength concerns during planned or unplanned outage events affecting one or more 132 kV transmission lines supplying the North Country.
Call for NCESS Submissions
Western Power invites NCESS Submissions from prospective NCESS providers to deliver Reliability Services and/or System Strength Services located in the North Country. The North Country is defined as the area supplied by the Rangeway, Geraldton and Chapman substations. This tender relates to the Long-Term contract term option (10-25 year terms). Proponents may offer a solutio...
- Issued by
- Western Power
- Closing Date
- 01/Feb/2027 05:00 PM (UTC+08:00) Perth time
- Reference number
- VP524329
- Contact person
- Peter Ling Email: peter.ling@westernpower.com.au Tel: 0893266185
- Tender categories
- Utilities
- Specification Docs
- 3
Is this tender for you?
- Time leftCloses 1 February 2027.
- It asks for1 eligibility point. See them below.From the tender's own page
- Documents3 documents listed on the portal. We hold none of them.Not held
How to respond
Who can apply
- Prospective NCESS providers to deliver Reliability Services and/or System Strength Services located in the North Country (defined as the area supplied by the Rangeway, Geraldton and Chapman substations)
Read from the tender's own page. Check the documents on the portal before you rely on this.
Summary of the published description
Western Power is conducting a Non-Co-optimised Essential System Services (NCESS) procurement process for long-term (10-25 year terms) Reliability and System Strength Services for the North Country. The proposed services aim to address reliability and system strength concerns during planned or unplanned outage events affecting one or more 132 kV transmission lines supplying the area. Submissions are invited from prospective providers to deliver Reliability Services and/or System Strength Services located in the North Country, defined as the area supplied by the Rangeway, Geraldton, and Chapman substations.Show moreShow less
Contract awards for similar work
Matched by title words (heuristic)6 awards with “strength” and “system” in the title; 4 publish a value: AUD 77,440 to 633,669, median 378,070. Not a price guide for this tender.
| Contract | Awarded | Value (AUD) |
|---|---|---|
CW00756_Access Scheme and System Strength Development services for New England REZ Energy Corporation of NSW · New South Wales | published 21 Jan 2026 | 633,669 |
AER - System Strength Guideline Development Australian Competition and Consumer Commission · Australia (Commonwealth) | 28 Jun 2024 | 77,440 |
Provision of Pavement Materials & Pre-Coated Screenings for Isis Highway at Various Locations Supply & Deliver road paving materials and screenings. REQUIREMENTS & TIMING Location 1: Voss Road Intersection (25 km) Location 2: Foleys Road Intersection (31 km) Location 3: Alfs Road Intersection (33 km) Location 4: Logging Creek Intersection (36.5 km) Location 5: Widening works 30.75-34.5 km The collective quantities required are as follows 10,000 tonne Type 2.1 pavement material 7,500 tonne Type 2.3 pavement material 1,500 tonne CBR10 material 300 tonne 10mm precoated aggregate 500 tonne 14mm precoated aggregate Note: Screenings will be delivered into stockpile. However all paving materials due to the nature of the works (ie narrow widenings) will need to be delivered in sidetippers. Project Specification General All work associated with the Offer shall be performed in accordance with the Department’s Technical Standard: - MRS05 (11/20) – Unbound Pavements - MRS22 (07/20) – Cover Aggregate. - MRS50 (09/20) – Specific Quality System Requirements A copy of these specifications are available from www.tmr.qld.gov.au or by contacting the project manager. Testing Requirements The Offeror shall undertake testing of the material using a NATA Certified Laboratory for the scope of testing required and registered (unconditional) with the Department of Transport and Main Roads as a CMT Supplier. This laboratory shall not subcontract any part of the scope of testing without express approval of the customer. Paving Material – Type 2.1 & 2.3 Maximum 5000 tonne lot Material Property Normal Testing Level Particle size distribution Q103A 1 per 1000 tonne Fines ratio (fines ratio, 0.075mm to 0.425mm sieves) 1 per 1000 tonne Liquid limit – Q104A 1 per 1000 tonne Plastic limit and plasticity index – Q105 1 per 1000 tonne Linear shrinkage – Q106 1 per 1000 tonne Linear shrinkage x% passing 0.425mm sieve 1 per 1000 tonne California bearing ratio – Q113A – ONLY for Type 2.3 1 per 2500 tonne Flakiness index – Q201 1 per 5000 tonne Wet/dry strength variation – Q205C See Note below Degradation factor – Q208B See Note below Ten percent fines value – Q205B See Note below Note: As per the Approved Testing Frequency Level of the Quarry Registration Certificate, for the specific quarry Cover Aggregate Material – For each material property, a minimum of one (1) test result shall be available which is traceable to the material in stockpile. Source Rock Tests: Max Lot Size 5000t Material Property Normal Testing Level Ten percent fines value (wet) – Q205B as per the Approved Testing Frequency Level of the Quarry Registration Certificate, for the specific quarry Wet/dry strength variation – Q205C Degradation factor – Q208B Water Absorption – Q214B Product Tests: Max Lot Size 1000t Particle size distribution - Q103B 1 test per 1000t Flakiness index – Q201 Average least dimension – Q202 Degree of precoating – Q217 Weak particles 2 – Q216 Crushed particles 1, 2 – Q215 1 test per 5000t 1 Required only where aggregate is obtained from other than a blasted quarry face 2 Testing to be undertaken on product prior to pre-coating Material Conversion: - For the purposes of evaluation each Offeror shall include details of the relevant conversion rates of the respective materials. Transport and Main Roads · Queensland | 20 Oct 2021 | 594,880 |
Provision of Pavement Materials & Pre-coated Screenings Supply & Deliver road paving materials and screenings. REQUIREMENTS & TIMING Location 1: Goodwood Road and Foleys Rd Intersection 1,000 tonne Type 2.1 pavement material 1,500 tonne Type 2.3 pavement material 500 tonne CBR10 material 25 tonne 10mm precoated aggregate 75 tonne 14mm precoated aggregate Note: Screenings will be delivered into stockpile however all paving materials will be delivered directly onto the road. Location 2: Goodwood Road and Garryowen Rd Intersection 250 tonne Type 2.1 pavement material 375 tonne Type 2.3 pavement material 200 tonne CBR10 material 25 tonne 10mm precoated aggregate 75 tonne 14mm precoated aggregate Project Specification General All work associated with the Offer shall be performed in accordance with the Department’s Technical Standard: - MRS05 (11/20) – Unbound Pavements - MRS22 (07/20) – Cover Aggregate. - MRS50 (09/20) – Specific Quality System Requirements A copy of these specifications are available from www.tmr.qld.gov.au or by contacting the project manager. Testing Requirements The Offeror shall undertake testing of the material using a NATA Certified Laboratory for the scope of testing required and registered (unconditional) with the Department of Transport and Main Roads as a CMT Supplier. This laboratory shall not subcontract any part of the scope of testing without express approval of the customer. Paving Material – Type 2.1 & 2.3 Maximum 5000 tonne lot Material Property Normal Testing Level Particle size distribution Q103A 1 per 1000 tonne Fines ratio (fines ratio, 0.075mm to 0.425mm sieves) 1 per 1000 tonne Liquid limit – Q104A 1 per 1000 tonne Plastic limit and plasticity index – Q105 1 per 1000 tonne Linear shrinkage – Q106 1 per 1000 tonne Linear shrinkage x% passing 0.425mm sieve 1 per 1000 tonne California bearing ratio – Q113A – ONLY for Type 2.3 1 per 2500 tonne Flakiness index – Q201 1 per 5000 tonne Wet/dry strength variation – Q205C See Note below Degradation factor – Q208B See Note below Ten percent fines value – Q205B See Note below Note: As per the Approved Testing Frequency Level of the Quarry Registration Certificate, for the specific quarry Cover Aggregate Material – For each material property, a minimum of one (1) test result shall be available which is traceable to the material in stockpile. Source Rock Tests: Max Lot Size 5000t Material Property Normal Testing Level Ten percent fines value (wet) – Q205B as per the Approved Testing Frequency Level of the Quarry Registration Certificate, for the specific quarry Wet/dry strength variation – Q205C Degradation factor – Q208B Water Absorption – Q214B Product Tests: Max Lot Size 1000t Particle size distribution - Q103B 1 test per 1000t Flakiness index – Q201 Average least dimension – Q202 Degree of precoating – Q217 Weak particles 2 – Q216 Crushed particles 1, 2 – Q215 1 test per 5000t 1 Required only where aggregate is obtained from other than a blasted quarry face 2 Testing to be undertaken on product prior to pre-coating Material Conversion: - For the purposes of evaluation each Offeror shall include details of the relevant conversion rates of the respective materials. Transport and Main Roads · Queensland | 9 Sep 2021 | 161,260 |
Darwin - Consultancy - System Strength Impact Assessment Guidelines Power and Water Corporation · Northern Territory | Not published |
Showing 5 of 6.